Spectrophotometer ,Colorimeter, Gloss Meter

ESSER/Sine Image DNP 11 Steps Grayscale Camera Test Chart

DNP 11 Steps Grayscale Camera Test Chart

Brand :ESSER/Sine Image
Model Number:TE83
Size:280 x 210mm
Ratio:4:3
Model:Reflective / Transmission


DNP 11 steps grayscale test chart are used for test grayscale of camera.It is normally used with desktop color assessment cabinet or hanging on the wall.Those grey modules are displayed in a reverse chronological order based on a grey backgroup (D≈0.62),those gray scale are marked by log level (gamma=0.45).Contrast range for this chart is 40:1.

 
Technical Parameters:

Grayscale Density Reflective%
1 0.05 89
2 0.13 74
3 0.22 60
4 0.32 48
5 0.43 37
6 0.55 28
7 0.69 20
8 0.86 14
9 1.06 9
10 1.31 5
11 1.65 2
The density value for white area which is in the middle of  two grayscale D=0.05(Reflectivity=89%)。
There are two models about 11 steps grayscale test chart,(γ=1.0) or (γ=0.45)
Following are the reflectivity and grayscale density value about the grayscale (γ=1.0) :

Grayscale 1
(white)
2 3 4 5 6 7 8 9 10 11 Background
Reflectivity(%) 83.0 74.9 66.8 58.7 50.6 42.5 34.4 26.3 18.2 10.1 2.0 18.0
Density Value 0.08 0.13 0.18 0.23 0.30 0.37 0.46 0.58 0.74 1.00 1.70 0.74
 
Following are the reflectivity and grayscale density value about the grayscale (γ=0.45) :
 

Grayscale 1
(white)
2 3 4 5 6 7 8 9 10 11 Background
Reflectivity(%) 83.0 71.0 57.0 46.0 37.0 27.4 19.5 13.4 8.3 4.75 2.0 18.0
Density Value 0.08 0.15 0.24 0.34 0.43 0.56 0.71 0.87 1.08 1.32 1.70 0.74
 
How to use it?

Adjust the camera aperture to the brightness point when the waveform monitor’s video signal reached 100%. Then use a calibrated camera with IT U BT.709 standard and the darkness modules will be reached 10% signal level.
 